Supported meters

Works with the meters already in your switchgear

MeterSight reads any Modbus TCP device with a register map, ships verified presets for the most common power meters, and adds automatic COMTRADE waveform retrieval in Gold. Every access is read-only.

Register-map presets

Modbus TCP presets

Presets cover currents, voltages, power, power factor, frequency, signed 64-bit cumulative energy, disturbance counters and THD where the meter provides them. Only registers documented as read-only are included.

Modbus TCP register-map presets
MeterMap statusCoveragePackages
Schneider PowerLogic PM8000Firmware map verifiedCurrents A/B/C/N, averages and unbalance; L-L and L-N voltages; per-phase and total kW, kVAR, kVA; frequency; power factor; delivered and received energy; disturbance counters; 3-second THD; K-factor; crest factorBronze, Silver, Gold
Schneider PowerLogic ION9000Firmware map verifiedAs PM8000, plus transient counterBronze, Silver, Gold
Schneider PowerLogic PM5500Preset, lab validation recommendedStandard electrical and energy pointsBronze, Silver, Gold
Socomec DIRIS A-200Official 333 mV mapStandard electrical and energy pointsBronze, Silver, Gold
Socomec DIRIS MCM-48Official fixed mapMulti-circuit, flat and hotel mode, 1000-register load strideBronze, Silver, Gold
Socomec DIRIS MCM-16Official fixed mapMulti-circuitBronze, Silver, Gold
Powerside PQube 3Preset, lab validation recommendedBase 0x7000, unit ID 1, TCP 502, big-endianBronze, Silver, Gold
Any other Modbus TCP meterCustom mapDefine holding and input registers, scaling and data types in SetupBronze, Silver, Gold

Protocols

How MeterSight talks to devices

Modbus TCP

Function codes 03 (holding) and 04 (input) only. No write path exists in the poller. All packages

SFTP for COMTRADE

Read-only retrieval from PM8000 and ION9000, 16 KB reads, content-hash de-duplication. Gold

SMTP and SNMP

Outbound only: STARTTLS or implicit TLS email, and SNMP traps to your NMS. Silver: SMTP Gold: both

Serial meters

Meters on RS-485?

MeterSight polls Modbus TCP. Meters on RS-485 Modbus RTU reach MeterSight through a standard Modbus TCP-to-RTU gateway, which presents each serial device as a unit ID behind one IP address. Most switchgear vendors ship one; we can recommend models that we have commissioned.

Not sure whether your meter is supported? Send us the model and firmware version. If it publishes a register map, we will tell you what MeterSight can read from it before you install anything.

Tell us what is in your gear

Send a meter list and we will confirm coverage, recommend a package and set up a trial license.