MeterSight Silver

Real-time power monitoring with MeterSight Silver

Silver takes everything in Bronze and adds real-time electrical values, continuous trending, harmonics and THD event detection, and a scheduled report engine that emails PDF and CSV reports on the cadence you choose.

Available in the cloud or on premises, with the same package features.

  • Live electrical values
  • Harmonics and THD
  • Scheduled reports
  • Read-only meter access

Who it is for

Live electrical data for plant and facility engineers

Live visibility plus automated reporting. Watch voltage, current, power and harmonics in real time, and let the reports send themselves.

Highlights

  • Everything in Bronze
  • Live values, continuous trending and power snapshots
  • Harmonic spectrum and voltage THD event timeline
  • Recording modes: snapshot, average, min and max at 1 s to 24 h
  • Scheduled email reports (daily, weekly, monthly, billing-cycle close)
  • Demand, power-factor and electrical health summaries

Live electrical values

Watch the plant breathe

Silver reads the full electrical picture from every meter: phase and average voltages, currents, active, reactive and apparent power, power factor and frequency. The Power screen shows the whole site at once; the Continuous Trend chart shows how it got there.

  • Read intervals from 1 second to 24 hours per meter
  • Recording modes: historical only, live only, or both
  • Store snapshot, average, minimum, maximum, or all three
  • Power Snapshot, Demand Health and Power Factor Health cards
  • Weather and load snapshot for context on unusual days
MeterSight Silver Continuous Power Monitoring screen with live real, reactive and apparent power, power factor, demand, voltage, current and frequency, a continuous demand trend with weather overlay, and power snapshot, demand health and weather cards.
Silver: Continuous Power Monitoring
MeterSight Silver Continuous Electrical Health screen with live voltage, current, power, THD, power factor and frequency, a continuous voltage trend, harmonic snapshot with spectrum, power factor health gauge and power quality snapshot.
Silver: Continuous Electrical Health with harmonic snapshot and THD events

Harmonics and THD

Catch distortion before it cooks a drive

Silver adds the power-quality screens most facilities need day to day. Full waveform and ITIC analysis is in Gold.

Harmonic snapshot and spectrum

Voltage and current THD with a per-order harmonic spectrum from meters that report it, so you can see whether the 5th and 7th are climbing.

Voltage THD events

Set a THD threshold and Silver records events with a timeline, so intermittent distortion from a new load shows up as a pattern instead of a rumour.

Electrical health summary

Plain-language summaries of demand, power factor and distortion for the week, ready to paste into a maintenance report.

Scheduled report engine

  • Daily, weekly, monthly or on billing-cycle close
  • PDF, CSV or both attached to each email
  • Up to 20 schedules per site and 20 recipients per schedule
  • SMTP with STARTTLS by default, implicit TLS available, private CAs supported
  • Durable PostgreSQL delivery queue with 180 days of delivery history
  • Attachment cap of 15 MB per message

Automated reporting

Reports that send themselves

Point Silver at your mail server once. From then on, the billing-cycle summary lands in the finance inbox the morning the cycle closes, and the weekly electrical health summary reaches the maintenance lead every Monday. Delivery is queued in the database, so a mail-server outage delays a report rather than losing it.

Every message carries the same branded PDF you can export by hand, with the MeterSight logo and your site name on every page.

Honest scope

What Silver does not include

We would rather you pick the right package than the biggest one. These capabilities live in a higher package.

  • Alarm engine, escalation, acknowledgment and alarm audit
  • Graphics engine: campus, building, switchgear and one-line views
  • ITIC/CBEMA analysis and COMTRADE waveform viewer
  • Live sag and swell event detection
  • SNMP traps and Store & Forward
  • Operator and viewer roles and forced row-level security

On-premises specifications

MeterSight Silver on-premises technical specifications
Operating systemWindows 10 / 11 or Windows Server, x64. Administrator rights to install.
Runs asWindows service "MeterSight Silver" with delayed start and automatic recovery
Install locationC:\Program Files\MeterSight Silver
Web interfacehttp://localhost:8082 (any modern browser on the LAN; HTTPS via a same-host reverse proxy)
DatabaseBundled PostgreSQL 18 on loopback, or your own managed PostgreSQL with TLS
RuntimeBundled Node.js 22 runtime, no separate install
License key prefixMSS- keys, one activated computer per key
ActivationOnline, or fully offline with a signed license file bound to the machine ID
Meter protocolModbus TCP, read-only (function codes 03 and 04)

FAQ

MeterSight Silver questions

How fast can Silver poll?
Down to one second per meter. Silver's poller staggers start times, caps concurrency and backs off on failures, so a busy site does not turn into a storm of Modbus requests.
Does Silver need an internet connection to send email?
Scheduled email reports need a route to the configured SMTP server. On-premises Silver can use a mail server inside your network; MeterSight Cloud requires connectivity to the hosted service.
Can Silver detect voltage sags?
Silver records voltage THD events and trends voltage continuously, but dedicated sag and swell event detection with ITIC classification is a Gold capability.

Explore MeterSight Silver

Talk with us about your meters and monitoring requirements. A free 7-day trial is available for the on-premises version.

Plan your demand monitoring and deployment

Peak demand monitoring

Review 15-minute demand alongside live power trends, then investigate the loads behind a peak.